Thermo Dma Data-Cal Calibrator, Model 1905-050

FDA 510(k) K022108 · Thermo Dma, Inc.

Substantially Equivalent

510(k) numberK022108

Submission

Device name
Thermo Dma Data-Cal Calibrator, Model 1905-050
Applicant
Thermo Dma, Inc.
Arlington, TX, US
Received
June 28, 2002
Decision date
July 25, 2002
Decision
Substantially Equivalent (SESE)
Type
Traditional 510(k)
Summary
510(k) summary available from FDA

Official FDA 510(k) record

Device classification

Product code
JIX – Calibrator, Multi-Analyte Mixture
Device class
Class II (moderate risk)
Regulation
21 CFR 862.1150
Specialty
Clinical Chemistry

Other 510(k)s with product code JIX

510(k)DeviceApplicantDecision
K161140VITROS Chemistry Products Calibrator Kit 3JIX · Abbreviated Ortho-Clinical Diagnostics, Inc.05/20/2016SE
K153365ADVIA Chemistry Enzyme 1 Calibrator, ADVIA Chemistry Enzyme 2 CalibratorJIX · Traditional Siemens Healthcare Diagnostics, Inc.12/18/2015SE
K151552ELITech Clinical Systems ELICAL 2, ELITech Clinical Systems ELITROL I, ELITech Clinical…JIX · Abbreviated Elitechgroup07/08/2015SE
K140790Dimension Vista Chemistry 1 Calibrator (CHEM 1 CAL), Dimension Vista Magnesium Flex…JIX · Traditional Siemens Healthcare Diagnostics06/15/2015SE
K141388System CalibraterJIX · Abbreviated Beckman Coulter Ireland, Inc.07/11/2014SE
K133330C.F.A.S. Proteins, C.F.A.S. Pac, Precicontrol Clinchem Multi 1 & 2, Precinorm Protein &…JIX · Special Roche Diagnostics11/26/2013SE
K130765Elitech Clinical Systems Elical 2; Elitech Clinical Systems Elitrol I, Elitech Clinical…JIX · Abbreviated Elitechgroup04/04/2013SE
K123321Dimension Chemistry III CalibratoryJIX · Traditional Siemens Healthcare Diagnostics02/15/2013SE
K123372Abbott Lipid Multi Constituent CalibratorJIX · Traditional Abbott Laboratories01/14/2013SE
K122398Rapidpoint 500 System Measurement Cartridge with CalibratorsJIX · Traditional Siemens Healthcare Diagnostics, Inc.10/12/2012SE

More from Siemens Healthcare Diagnostics, Inc.

510(k)DeviceDecision
K012878Thermo Trace Ammonia Standards Set, Models TR-609JIS · Abbreviated 10/16/2001SE
K012518Trace Scientific Alkaline Phosphatase, Two Part Liquid, Model TR-113CJE · Abbreviated 10/09/2001SE
K012525Thermo Dma Fructosamine Assay, Model 7500-135/235LCP · Abbreviated 10/04/2001SE

Questions and answers

When was Thermo Dma Data-Cal Calibrator, Model 1905-050 cleared by the FDA?

Thermo Dma Data-Cal Calibrator, Model 1905-050 (K022108) received a 510(k) decision of Substantially Equivalent on July 25, 2002, 27 days after the submission was received.

What is the product code of K022108?

The FDA product code is JIX – Calibrator, Multi-Analyte Mixture, a Class II (moderate risk) device regulated under 21 CFR 862.1150.