CESIUM-137 Microseed Source Train Assembly/Shield
FDA 510(k) K894409 · Amersham Corp.
510(k) numberK894409
Submission
- Device name
- CESIUM-137 Microseed Source Train Assembly/Shield
- Applicant
- Amersham Corp.
Arlington Heights, IL, US - Received
- July 17, 1989
- Decision date
- September 29, 1989
- Decision
- Substantially Equivalent (SESE)
- Type
- Traditional 510(k)
Other 510(k)s with product code IWA
| 510(k) | Device | Applicant | Decision |
|---|---|---|---|
| K915253 | IR-192 Implant, ModificationIWA · Traditional | Omnitron Intl., Inc. | 02/27/1992SE |
| K874895 | IR-192 ImplantIWA · Traditional | Rads S.L., Inc. | 02/25/1988SE |
| K850382 | Iridium SeedsIWA · Traditional | Radiation Safety & Nuclear Products, Inc. | 08/15/1985SE |
| K844248 | IR-192 ImplantIWA · Traditional | Rads S.L., Inc. | 04/10/1985SE |
| K850726 | Wire Cutters, Brachytherapy-Table Top & Hand HeldIWA · Traditional | Syncor Intl. Corp. | 03/26/1985SE |
| K850163 | Iridium 192 WiresIWA · Traditional | Syncor Intl. Corp. | 03/26/1985SE |
| K771878 | Iridium 192 Wires & PinsIWA · Traditional | Cis Radiopharmaceuticals, Inc. | 10/27/1977SE |
More from Cis Radiopharmaceuticals, Inc.
| 510(k) | Device | Decision |
|---|---|---|
| K914135 | Amerlite(Tm) PROLACTIN-30 Assay, LAN.0086/2086CFT · Traditional | 02/18/1992SE |
| K912733 | Amerlex-M Specific Estrol(Unconjugated) Ria KitCIG · Traditional | 07/22/1991SE |
| K912766 | Amerlite Ck-Mb AssayJHY · Traditional | 07/17/1991SE |
| K904666 | Amerlite TSH-60 Assay Product Code: Lan. 0008/2008JLW · Traditional | 11/02/1990SE |
| K902760 | Amersham TSH Control SeraJJX · Traditional | 07/27/1990SE |
| K901857 | GADOLINIUM-153 Bone Densitometer (GDC.10413)KGI · Traditional | 07/09/1990SE |
| K901854 | GADOLINIUM-153 Bone Densitometer (GDC.10411/10412)KGI · Traditional | 07/09/1990SE |
| K901848 | GADOLINIUM-153 Bone Densitometer SourcesKGI · Traditional | 07/09/1990SE |
| K901832 | GADOLINIUM-153 Bone Densitometer Sources GDC.10415KGI · Traditional | 07/09/1990SE |
| K896270 | Amerlite ESTRADIOL-60 Assay LAN.0081/2081CHP · Traditional | 12/12/1989SE |
Questions and answers
When was CESIUM-137 Microseed Source Train Assembly/Shield cleared by the FDA?
CESIUM-137 Microseed Source Train Assembly/Shield (K894409) received a 510(k) decision of Substantially Equivalent on September 29, 1989, 74 days after the submission was received.
What is the product code of K894409?
The FDA product code is IWA – Source, Wire, Iridium, Radioactive, a Class II (moderate risk) device regulated under 21 CFR 892.5730.