Cyberonics, Inc

Medical device manufacturer in Houston, TX.

1510(k) clearances
0PMA approvals
23recalls

Device types

510(k) clearances

510(k)DeviceDecision
K092364Model 220 Patient MagnetDTG · Traditional 11/03/2009SE

Recalls

RecallProductInitiated
Z-0555-2018 Class IIVNS(R) Therapy Programmer, GMDN: 44077, Model 3000 v1.0.2.2 Intended Use/Indications:…Two Model 3000 Programmers were distributed in error by prior to FDA approval of version 1.0.2.2 software. 12/02/2017Terminated
Z-2255-2018 Class IIVNS Therapy Programmer, Model 3000, v1.0 SystemCertain Model 3000 programming events can result in miscalculation of parameters stored in the Models 103… 11/13/2017Terminated
Z-3020-2017 Class IIVNS Therapy AspireHC Generator, VNS Therapy AspireSR Generator. Model No. 106. Product…Manufacturing process used to assemble the circuit board may result in some devices experiencing a faster… 06/13/2017Terminated
Z-3019-2017 Class IIVNS Therapy AspireHC Generator, VNS Therapy AspireSR Generator. Model No. 105. Product…Manufacturing process used to assemble the circuit board may result in some devices experiencing a faster… 06/13/2017Terminated
Z-0659-2016 Class IIVNS Therapy AspireSR Generator Model 106. Indicated for use as an adjunctive therapy in…Recall being initiated in response to three reports of "Burst Watchdog Timeout" events occurring with the… 12/18/2015Terminated
Z-0645-2016 Class IICyberonics Vagus Nerve Stimulator VNS Therapy AspireSR Generator, Model 106Certain Model 106 Pulse Generators demonstrate delays in sensing during use of the 'Verify Heartbeat… 11/18/2015Terminated
Z-0280-2016 Class IICyberonics Vagus Nerve Stimulator (VNS) Therapy AspireSR Generator, Model 106Certain Model 106 Pulse Generators demonstrate delays in sensing during use of the 'Verify Heartbeat… 10/07/2015Terminated
Z-1526-2015 Class IIVNS Therapy DemiPulse Generator Model 103 and VNS Therapy DemiPulse Duo Generator Model…The pulse generators have a lower battery longevity than specified in their design requirement as a result… 03/06/2015Terminated
Z-0858-2015 Class IICyberonics VNS Therapy AspireHC, Model 105 Generator. The Cyberonics VNS Therapy System…The recalled product was distributed with an incorrect serial number printed on the device's label. 11/20/2014Terminated
Z-0210-2012 VNS Therapy Aspire HC Generator and VNS, Model 105 Cyberonics, Inc. 100 Cyberonics…The devices are being recalled because the output current delivered to the vagus nerve is less than the… 08/12/2011Terminated
Z-0006-2012 Model 104 VNS Therapy Demipulse Duo Generator Cyberonics, Inc. Houston, Texas, Model 104…An investigation was initiated based on a report from the field in which an Intensive Follow-up Indicator… 05/06/2011Terminated
Z-0005-2012 VNS Therapy Demipulse Model 103 Generator Cyberonics, Inc. Houston, Texas, Model 103…An investigation was initiated based on a report from the field in which an Intensive Follow-up Indicator… 05/06/2011Terminated
Z-1591-2010 VNS Therapy Demipulse Generator, Model 103 and VNS Therapy Demipulse Duo Generator…Battery life projection is inaccurate. 04/06/2010Terminated
Z-0642-2010 VNS Therapy Demipulse Generator, Model 103 and VNS Therapy Demipulse Duo Generator…Under certain conditions, product's battery life can be reduced. 11/20/2009Terminated
Z-0264-2010 Cyberonics VNS Therapy Programming M250 Programming System, model number 250, version…Some VNS Therapy System replacement Demipulse generators reporting low lead impedance readings. In rare… 07/24/2009Terminated
Z-0995-2009 Cyberonics VNS Therapy Demipulse Duo Generator, Model 104; an implantable…Reset/disabling of the VNS Therapy Demipulse Generator and Demipulse Duo Generator due to magnet… 02/07/2008Terminated
Z-0994-2009 Cyberonics VNS Therapy Demipulse Generator, Model 103; an implantable…Reset/disabling of the VNS Therapy Demipulse Generator and Demipulse Duo Generator due to magnet… 02/07/2008Terminated
Z-0568-2008 Cyberonics, VNS Therapy System Model 250 Handheld programming system using Dell x5…Screen Freezes-- The Dell X5 Handheld PC screen will freeze caused due to incompatibility between the… 10/25/2007Terminated
Z-0173-2008 Cyberonics VNS Therapy Perrennia Lead, Model #303; Sterile, Single use only; distributed…Dissolution/Fractures to the leads of the VNS Therapy System 08/02/2007Terminated
Z-0172-2008 Cyberonics VNS Therapy Bipolar Lead, Model #302; Sterile, Single use only; Distributed…Dissolution/Fractures to the leads of the VNS Therapy System 08/02/2007Terminated
Z-0171-2008 Cyberonics Neuro Cyberonics Prosthesis System NCP Bipolar Lead, Model #300; Sterile…Dissolution/Fractures to the leads of the VNS Therapy System 08/02/2007Terminated
Z-0342-2007 Handhelds-Cyberonics VNS Therapy System, Model 250-''Handhelds'' preprogrammed with…During programming, pulse generator may be inadvertently set to 8.0 mA output, regardless of the mA range… 10/17/2006Terminated
Z-0341-2007 Cyberonics VNS Therapy System, Model 250-''HAND HELD'' programming software v6.1…During programming, pulse generator may be inadvertently set to 8.0 mA output, regardless of the mA range… 10/17/2006Terminated