NeuroLogica Corporation

Medical device manufacturer in Danvers, MA.

8510(k) clearances
0PMA approvals
13recalls

Device types

510(k) clearances

510(k)DeviceDecision
K250928OmniTom Elite with PCDJAK · Traditional 09/08/2025SE
K233767OmniTom EliteJAK · Traditional 06/10/2024SE
K213649BodyTom 64JAK · Traditional 04/29/2022SE
K171183OmniTomJAK · Traditional 08/18/2017SE
K142697NExCT 7JAK · Traditional 12/23/2014SE
K102677Bodytom NL 4000JAK · Traditional 03/24/2011SE
K090811Inspira HD, Model: NL1000KPS · Abbreviated 08/27/2009SE
K051765Ceretom, Model NL3000JAK · Traditional 07/14/2005SE

Recalls

RecallProductInitiated
Z-0480-2026 Class IIGM85 Digital Mobile X-ray imaging System; Model Number: GM85;The four (4) M5 bolts that secure the Tube Head Unit to the end of the arm may loosen or fracture due to… 10/07/2025Open, Classified
Z-2715-2024 Class IIGM60A. Digital Diagnostic Mobile X-Ray System.Potential for the anti-fall system of the device arm to fail. 07/08/2024Open, Classified
Z-1056-2024 Class IISamsung Digital Diagnostic Mobile X-ray System, Model GM85.Mobile x-ray systems moving arm frame welding issue which presents the potential of bodily harm due to fall… 12/28/2023Open, Classified
Z-2068-2023 Class IIOmniTom/OmniTom Elite- X-ray computed tomography applications for anatomy that can be…1. Wheels loosening over time with use of the device could lead to the inability to effectively drive the… 06/06/2023Open, Classified
Z-1414-2023 Class IISamsung GM85 Digital X-ray Imaging System-A Digital Diagnostic Mobile X-ray SystemIssue related to the operation of the arm latch within the column that supports the arm, potential bodily… 03/08/2023Open, Classified
Z-2772-2020 Class IIOmniTom Computed tomography x-ray system, Model NL5000, all NL5000 systems with software…There are potential issues related to the operational state of the scanner, specifically for transport and… 07/15/2020Terminated
Z-2276-2019 Class IIWS80A Diagnostic Ultrasound System Version 1.00.16, 3.00.17, 3.00.18, 3.00.19, 3.01.00…There is a potential for probes overheating when decreasing the Doppler SV (Sample Volume) size value set by… 07/25/2019Terminated
Z-2275-2019 Class IIHS70A Diagnostic Ultrasound System Version 2.01.00, 2.01.01, 2.01.02, 2.01.03, 2.01.04…There is a potential for probes overheating when decreasing the Doppler SV (Sample Volume) size value set by… 07/25/2019Terminated
Z-1691-2019 Class IISamsung GM85 Mobile Digital X-ray Imaging System Product Usage: The GM85 Digital X-ray…Potential issue related to the operation of the safety latch within the column that supports the arm due to… 05/06/2019Terminated
Z-1391-2018 Class IISolid state x-ray imager (flat panel/digital imager) Solid state x-ray imager (flat…While transporting the portable machine with the retrofit equipment in a backwards motion, there is… 01/12/2018Terminated
Z-0726-2018 Class IIThe GC80 Digital X-ray Imaging SystemAn image was obtained with over exposure during a Thorax examination using the AEC function. 06/22/2017Terminated
Z-3036-2017 Class IISamsung GU60A system- Digital X-ray Imaging Systems are intended for use in generating…When performing the Stitching function on GU60A system, unintended area is exposed to radiation 05/24/2017Terminated
Z-0263-2016 Class IISamsung GM60A-40S Intended for use in generating radiographic images of human anatomy.When the system is driving over a non-conductive floor and then over a conductive, grounded part, proper… 09/14/2015Terminated