Luminex Corporation

Medical device manufacturer in Northbrook, IL.

18510(k) clearances
0PMA approvals
40recalls

Device types

510(k) clearances

510(k)DeviceDecision
K253722LIAISON PLEX Gastrointestinal Flex AssayPCH · Traditional 05/19/2026SE
K243490LIAISON PLEX Gram-Positive Blood Culture AssayPAM · Traditional 06/06/2025SE
K243013LIAISON PLEX Gram-Negative Blood Culture AssayPEN · Traditional 04/18/2025SE
K240627LIAISON PLEX Yeast Blood Culture AssayPEO · Traditional 06/04/2024SE
K233410LIAISON PLEX Respiratory Flex AssayQOF · Traditional 03/01/2024SE
K191742ARIES MRSA AssayNQX · Traditional 09/25/2019SE
K172402ARIES Group A Strep Assay, ARIES Group A Strep Assay Protocol File KitPGX · Traditional 10/30/2017SE
K171441ARIES C. difficile Assay Complete Kit, ARIES C. difficile Assay Protocol File Kit, ARIES…OZN · Traditional 07/21/2017SE
K163626ARIES Bordetella Assay; ARIES Bordetella Assay Protocol File KitOZZ · Traditional 05/02/2017SE
K162772ARIES GBS AssayNJR · Traditional 12/23/2016SE
K161220ARIES® Flu A/B & RSV AssayOCC · Traditional 08/02/2016SE
K161495ARIES MI System, ARIES HSV 1&2 Assay Cassettes-Carton of 24 (IVD), ARIES HSV 1&2 Assay…OOI · Special 06/30/2016SE
K160517ARIES SystemOOI · Special 04/12/2016SE
K151917ARIES SystemOOI · Traditional 10/06/2015SE
K151906ARIES HSV 1&2 Assay Cassettes - Carton of 24 (IVD), ARIES HSV 1&2 Assay Protocol File…PGI · Traditional 10/06/2015SE
K133302Flexmap 3DNSU · Traditional 01/10/2014SE
K121399Luminex Flexmap 3D Instrument System, Luminex Xponent 4.0 Spi Software, Flexmap 3D IVD…NSU · Traditional 01/09/2013SE
K073506Luminex LX 100/200 InstrumentNSU · Traditional 03/07/2008SE

Recalls

RecallProductInitiated
Z-1903-2025 Class IIVERIGENE Gram Negative Blood Culture (BC-GN) Nucleic Acid Test, REF 20-006-021; for use…It was determined that the consumable issue may result in No Call - INT CTL 1 and/or False Negative results… 04/16/2025Completed
Z-2533-2024 Class IIVerigene Gram Positive Blood Culture (BC-GP) Nucleic Acid TestPotential for defective test cartridges which may result in false positive results for the Staphylococcus… 06/20/2024Open, Classified
Z-0500-2024 Class IILuminex VERIGENE BC-GP Utility Tray (5-Pack Carrier), Gram-Positive Blood Culture…Potentially defective utility trays in the reagent kits. 11/07/2023Open, Classified
Z-2024-2023 Class IIVERIGENE Clostridium difficile Nucleic Acid Test, REF 30-002-022It is possible that in rare instances the VERIGENE CDF Nucleic Acid Test Kit (Part No. 20-005-022) and the… 06/05/2023Open, Classified
Z-2023-2023 Class IIVerigene Enteric Pathogens Nucleic Acid Test (EP), REF 30-002-023It is possible that in rare instances the VERIGENE CDF Nucleic Acid Test Kit (Part No. 20-005-022) and the… 06/05/2023Open, Classified
Z-0134-2023 Class IIARIES SARS-CoV-2 Assay, REF: 50-10047A part defect with the wash 1 syringe of an SARS-CoV-2 assay could lead to incomplete extraction thereby… 09/14/2022Open, Classified
Z-1524-2022 Class IIARIES SARS-CoV-2 AssaySARS-CoV-2 assay that detects SARS-CoV-2 ORF1ab and N genes may not detect the ORF1ab gene. A positive… 07/14/2022Open, Classified
Z-1335-2022 Class IIVERIGENE Enteric Pathogens Nucleic Acid Test, Part No. 30-002-23There is a potential for false negative results using VERIGENE CDF Stool PREP KIT and VERIGENE EP Stool PREP… 06/17/2022Open, Classified
Z-1334-2022 Class IIVerigene CDF Nucleic Acid Test, Part No. 30-002-22There is a potential for false negative results using VERIGENE CDF Stool PREP KIT and VERIGENE EP Stool PREP… 06/17/2022Open, Classified
Z-1092-2022 Class IIVerigene Processor SP, Models 10-0000-07/10-0000-07R a component of the Verigene systemHeater within the Verigene System may be outside of established temperature limits for assays which could… 04/05/2022Open, Classified
Z-1109-2022 Class IIVERIGENE Nucleic Acid Test Kit-BC-GN Extraction Tray - 9.73 mL, REF 20-009-021Higher than normal "No Call Internal Control failures" due to a missing reagent within a small subset of the… 02/15/2022Open, Classified
Z-0553-2022 Class IIARIES HSV 1&2 Assay, Catalog/REF# 50-10017Impacted lot may leak inside the ARIES instrument. Testing confirmed a leak rate of 0.9%. Leaking cassettes… 11/17/2021Terminated
Z-2451-2021 Class IIVerigene EP Amplification Reagent Kit TestThere is potential for false positive results. 08/03/2021Open, Classified
Z-0498-2022 Class IIARIES HSV 1&2 Assay, Part Number/REF 50-10017Impacted lot may leak inside the ARIES instrument. 04/16/2021Terminated
Z-1488-2021 Class IIVERIGENE Processor SP - Product Usage: intended for processing and identifying nucleic…Potential for a false-negative result for Vibrio parahaemolyticus, Salmonella, and/or Shigella spp when used… 03/18/2021Open, Classified
Z-2011-2021 Class IIVerigene Gram Negative Blood Culture Nucleic Acid Test v2 (BC-GNv2) Model Number:…Potential for a false-negative result. 10/30/2020Open, Classified
Z-2010-2021 Class IIVerigene Clostridium difficile Nucleic Acid Test Kit (CDF) Model Number: 20-006-022Potential for a false-negative result. 10/30/2020Open, Classified
Z-2009-2021 Class IIVerigene Enteric Pathogens Nucleic Acid Test (EP) Model Number: 20-006-023Potential for a false-negative result. 10/30/2020Open, Classified
Z-2008-2021 Class IIVerigene Gram Negative Blood Culture Nucleic Acid Test (BC-GN) Model Number: 20-006-021Potential for a false-negative result. 10/30/2020Open, Classified
Z-2007-2021 Class IIVerigene Gram-Positive Blood Culture Nucleic Acid Test (BC-GP) Model Number: 20-006-018Potential for a false-negative result. 10/30/2020Open, Classified
Z-2006-2021 Class IIVerigene Respiratory Pathogens Flex Nucleic Acid Test (RP Flex) Model Number: 20-006-024Potential for a false-negative result. 10/30/2020Open, Classified
Z-0477-2021 Class IIVerigene Processor SP, Model Numbers 10-0000-07 and 10-0000-07R. Used with assay…Luminex has determined that three (3) separate test fixtures used by field service engineers to service the… 10/13/2020Terminated
Z-0476-2021 Class IIVerigene Processor SP, Model Numbers 10-0000-07 and 10-0000-07R. Used with assay:…Luminex has determined that three (3) separate test fixtures used by field service engineers to service the… 10/13/2020Terminated
Z-2776-2020 Class IIVerigene Processor SP with assay Luminex, VERIGENE Gram-Negative Blood Culture Nucleic…An instrument failure mode that may result in a Blood Culture Gram Positive (BC-GP) or Gram Negative (BC-GN)… 06/15/2020Terminated
Z-2775-2020 Class IIVerigene Processor SP with assay: Luminex, VERIGENE Gram-Positive Blood Culture Nucleic…An instrument failure mode that may result in a Blood Culture Gram Positive (BC-GP) or Gram Negative (BC-GN)… 06/15/2020Terminated
Z-0920-2022 Class IIVerigene Processor SP, Model Numbers: 10-0000-07 and 10-0000-07-RTwo of three complaints were initiated due to the customers repeatedly obtaining No Call results on the… 04/22/2019Open, Classified
Z-2288-2019 Class IIARIES Extraction Kit; ARIES System; SYNCT , REF 50-10026, UDI # 00840487100073Through internal investigation, it was discovered that a portion of side cassette assemblies (SCAs) back… 02/20/2019Open, Classified
Z-2287-2019 Class IIARIES C. difficile Assay , REF 50-10018, UDI # 00840487100059Through internal investigation, it was discovered that a portion of side cassette assemblies (SCAs) back… 02/20/2019Open, Classified
Z-2286-2019 Class IIARIES Group A Strep Assay , REF 50-10041, UDI # 00840487101469Through internal investigation, it was discovered that a portion of side cassette assemblies (SCAs) back… 02/20/2019Open, Classified
Z-2285-2019 Class IIARIES GBS Assay , REF 50-10021, UDI # 00840487100165Through internal investigation, it was discovered that a portion of side cassette assemblies (SCAs) back… 02/20/2019Open, Classified
Z-2284-2019 Class IIARIES Flu A/B & RSV Assay , REF 50-10020, UDI # 00840487100158Through internal investigation, it was discovered that a portion of side cassette assemblies (SCAs) back… 02/20/2019Open, Classified
Z-2283-2019 Class IIARIES HSV 1&2 Assay , REF 50-10017, UDI # 00840487100295Through internal investigation, it was discovered that a portion of side cassette assemblies (SCAs) back… 02/20/2019Open, Classified
Z-2282-2019 Class IIAries Bordetella Assay, REF 50-10037, UDI # 00840487101452Through internal investigation, it was discovered that a portion of side cassette assemblies (SCAs) back… 02/20/2019Open, Classified
Z-0822-2019 Class IIIVergene Amplification Tray - 700uL, BC-GP REF 20-011-018 The Verigene(R) Gram-Positive…On lot of VERIGENE(R) BC-GP Utility Kits (20-011-018) were labeled with the VERIGENE(R) Amplification Tray… 12/26/2018Terminated
Z-0054-2021 Class IIVERIGENE Processor SP Model No. 10-0000-07. An in vitro diagnostic device intended for…No results/incorrect results due to failure of the hybridization heater. 12/10/2018Open, Classified
Z-0445-2019 Class IIVERIGENE Blood Culture Gram-Positive Nucleic Acid Kits (packaged as five-pack carriers)…Potential to lead to a false negative results. 09/14/2018Terminated
Z-2292-2019 Class IILuminex Aries M1 System Model: Aries M6V1 Aries Software v1.0 For In Vitro Diagnostic…An incorrect control board and firmware installed in some of the Hand Held Barcode Scanners could result in… 06/29/2018Terminated
Z-2952-2018 Class IIVerigene Enteric Pathogens Nucleic Acid Test (EP) for detecting and identification of…Elevated false positive results Yersinia enterocolitica (Yersinia) from customers using the EP Nucleic Acid… 05/08/2018Terminated
Z-2094-2017 Class IIARIES System and ARIES M1 SystemThe hand-held barcode scanner that is used as an accessory to enter ARIES cassette and specimen… 04/19/2017Terminated
Z-3112-2011 xTAG CYP2D6 Kit v3 IVD For use with Luminex 100/200 Instrument Luminex Molecular…Inaccurate test results, due to possible defective primers, which could lead to incorrect dosage on… 05/24/2011Terminated