Table, Radiologic

FDA product code KXJ · Class II (moderate risk) · 21 CFR 892.1980 · Radiology

31510(k) clearances
0PMA approvals
27recalls

Manufacturers

510(k) clearances

510(k)DeviceApplicantDecision
K050190ApolloKXJ · Abbreviated Villa Sistemi Medicali S.P.A.03/25/2005SE
K963905Radiographic Itt TableKXJ · Traditional X-Ray Technologies, Inc.11/12/1996SE
K955414XRT 400KXJ · Traditional Wuestec Medical, Inc.07/24/1996SE
K951146Imaging TableKXJ · Traditional Septa Corp.05/04/1995SE
K950068Carbon Fiber Couch InsertKXJ · Traditional Medtec, Inc.04/06/1995SE
K950442Infrared Exposure Hand SwitchKXJ · Traditional Medical X-Ray Intl., Inc.03/31/1995SE
K940696Syncra Tilt Option for Angio Diagnost 5KXJ · Traditional Philips Medical Systems North America, Inc.03/16/1994SE
K931724Electrophysiology (Ep) Table Ep 2000 SeriesKXJ · Traditional Continental X-Ray Corp.06/14/1993SE
K926407Model Cole TAB-2 Table W/Model Cole SFD-2 SpotfilmKXJ · Traditional Nucletron-Oldelft Corp.03/31/1993SE
K922098CAG-02AKXJ · Traditional Toshiba America Medical Systems, In.C07/27/1992SE
K913121Omniflex Overhead Tubecrane CAT.#S-9108/#6713.400KXJ · Traditional Continental X-Ray Corp.08/16/1991SE
K883885Radkor, RF-159KXJ · Traditional Radkor, Inc.10/19/1988SE
K883155Rastix X-Ray TableKXJ · Traditional Bay X-Ray, Inc.09/06/1988SE
K881700Radkor KOB-84KXJ · Traditional Radkor, Inc.09/02/1988SE
K874934Universal Examination TableKXJ · Traditional Imatron, Inc.01/19/1988SE
K874639Remote-Controlled Universal Diag. Table RS-100KXJ · Traditional Shimadzu Precision Instruments, Inc.12/04/1987SE
K871827Omega III Angiographic Table, Rotation & StepperKXJ · Traditional General Electric Co.06/19/1987SE
K862144X-MatKXJ · Traditional Combined Concepts, Inc.06/25/1986SE
K860620Shampaine Radi-Op Model 1700RCKXJ · Traditional Smith & Nephew, Inc.04/08/1986SE
K854328Medex X-Ray TableKXJ · Traditional Philips Medical Systems (Cleveland), Inc.01/28/1986SE
K834478Chick/Reison Patient Emerg. TrolleyKXJ · Traditional Professional Medical Products, Inc.02/21/1984SE
K820111Siemens Sireskop 4KXJ · Traditional Siemens Corp.02/18/1982SE
K812791Portable Medical TableKXJ · Traditional Richard D. Spradlin11/24/1981SE
K811969Dual Pedestal TableKXJ · Traditional Philips Medical Systems (Cleveland), Inc.08/13/1981SE
K811196Allmec 90/15KXJ · Traditional Tecnomed, Inc.06/09/1981SE
K803120Tilting Imaging Table #846TKXJ · Traditional Quinton, Inc.01/22/1981SE
K790783Koordinat 3DKXJ · Traditional Siemens Corp.05/07/1979SE
K790743Coordinatus, Horizontal RadiographocKXJ · Traditional Pausch Corp.04/23/1979SE
K790692TelevixKXJ · Traditional General Electrical Espanola, S.A.04/23/1979SE
K790536ClearviewKXJ · Traditional Hipoint Research, Inc.03/28/1979SE
K781992Koordinat AngioKXJ · Traditional Siemens Corp.12/07/1978SE

Recalls

RecallProductFirmInitiated
Z-3034-2026 Class IIORT300, operating room table, ORT300 Modular Table Main Unit Assy Part Numbers…The linear actuator and rotational lock mechanism components may experience a mechanical failure that… IMRIS Imaging Inc08/06/2026Open, Classified
Z-1420-2025 Class IIBaxter TruSystem 7500 Hybrid Plus (SC), Product Code 1854088There is a software issue which causes the upper back section to not be operable/adjustable when the… Baxter Healthcare Corporation02/25/2025Open, Classified
Z-1416-2025 Class IIBaxter TruSystem 7500 Hybrid (MC), Product Code 1773204There is a software issue which causes the upper back section to not be operable/adjustable when the… Baxter Healthcare Corporation02/25/2025Open, Classified
Z-1415-2025 Class IIBaxter Floor mounting column TS 7500 U, Product Code 1730732There is a software issue which causes the upper back section to not be operable/adjustable when the… Baxter Healthcare Corporation02/25/2025Open, Classified
Z-1414-2025 Class IIBaxter Stationary column TruSystem 7500 U, Product Code 1730731There is a software issue which causes the upper back section to not be operable/adjustable when the… Baxter Healthcare Corporation02/25/2025Open, Classified
Z-1413-2025 Class IIBaxter Mobile column TruSystem 7500 U, Product Code 1730720There is a software issue which causes the upper back section to not be operable/adjustable when the… Baxter Healthcare Corporation02/25/2025Open, Classified
Z-2586-2021 Class IIOperating room table - Product Usage: intended for use during diagnostic examinations…ORT200/300 rotational lock may fail to function such that it cannot change states between locked and… Deerfield Imaging, Inc.08/25/2021Terminated
Z-2585-2021 Class IIOperating room table - Product Usage: intended for use during diagnostic examinations…ORT200/300 rotational lock may fail to function such that it cannot change states between locked and… Deerfield Imaging, Inc.08/25/2021Terminated
Z-2584-2021 Class IIOperating room table - Product Usage: intended for use during diagnostic examinations…ORT200/300 rotational lock may fail to function such that it cannot change states between locked and… Deerfield Imaging, Inc.08/25/2021Terminated
Z-0766-2020 Class IIApollo EZ, Model Number 9784152036 - Product Usage: The Apollo EZ remote-controlled…An amendment to the IFU and Service Manual is being issued to prescribe the replacement of the angulation… Villa Sistemi Medicali S.P.A.11/04/2019Open, Classified
Z-0765-2020 Class IIApollo DRF, Model Number 9784220831 - Product Usage: The remote controlled table Apollo…An amendment to the IFU and Service Manual is being issued to prescribe the replacement of the angulation… Villa Sistemi Medicali S.P.A.11/04/2019Open, Classified
Z-0764-2020 Class IIApollo, Model Numbers 9784100231, 9784120131, 9784130131 - Product Usage: Apollo table…An amendment to the IFU and Service Manual is being issued to prescribe the replacement of the angulation… Villa Sistemi Medicali S.P.A.11/04/2019Open, Classified
Z-0763-2020 Class IIJuno DRF, Model Number 709020 - Product Usage: General. multi-function x-ray systems…An amendment to the IFU and Service Manual is being issued to prescribe the replacement of the angulation… Villa Sistemi Medicali S.P.A.11/04/2019Open, Classified
Z-1753-2019 Class IIPrestilix 1600X Prestilix system is a fully integrated remote controlled digital…There has been a reported incident of a Distar CRT monitor that has fallen off the monitor wall mount… GE Healthcare, LLC03/29/2019Terminated
Z-0975-2018 Class IIIMRIS ORT100 Table, Part Number 110470-000The rotational locking mechanisms on the ORT 100/ T2X tables can become disengaged or unlocked while in use… Deerfield Imaging, Inc.02/20/2018Terminated
Z-1430-2017 Class IIApollo EZ; Model: 9784152036 Product Usage: General, multi-function x-ray systems…Patient fell from the table because the footrest of the device detached from the table top while the patient… Villa Sistemi Medicali S.P.A.12/27/2016Terminated
Z-1429-2017 Class IIApollo DRF; Model: 9784220831 Product Usage: General, multi-function x-ray systems…Patient fell from the table because the footrest of the device detached from the table top while the patient… Villa Sistemi Medicali S.P.A.12/27/2016Terminated
Z-1428-2017 Class IIApollo; Models: 9784000131 9784000231 9784020131 9784020231 9784100231 9784120131…Patient fell from the table because the footrest of the device detached from the table top while the patient… Villa Sistemi Medicali S.P.A.12/27/2016Terminated
Z-1427-2017 Class IIJuno DRF; Model: 709020 Product Usage: General, multi-function x-ray systems capable of…Patient fell from the table because the footrest of the device detached from the table top while the patient… Villa Sistemi Medicali S.P.A.12/27/2016Terminated
Z-1066-2017 Class IIApollo EZ: Model: 9784152036 Multi-function x-ray systems capable of routine radiograph…The analysis showed that the incident was caused by a chain of four faults: 1.) The injured person overcame… Villa Radiology Systems LLC02/19/2016Open, Classified
Z-1065-2017 Class IIApollo DRF: Model: 9784220831 Multi-function x-ray systems capable of routine radiograph…The analysis showed that the incident was caused by a chain of four faults: 1.) The injured person overcame… Villa Radiology Systems LLC02/19/2016Open, Classified
Z-1064-2017 Class IIApollo: Models: 9784000131, 9784000231, 9784020131, 9784020231, 9784100231, 9784120131…The analysis showed that the incident was caused by a chain of four faults: 1.) The injured person overcame… Villa Radiology Systems LLC02/19/2016Open, Classified
Z-1063-2017 Class IIJuno DRF; Model: 709020 Multi-function x-ray systems capable of routine radiograph and…The analysis showed that the incident was caused by a chain of four faults: 1.) The injured person overcame… Villa Radiology Systems LLC02/19/2016Open, Classified
Z-1079-2015 Class IIJuno DFR X-ray systemThe system does not provide the appropriate audible signal, permanent activation, and manual override… Villa Radiology Systems LLC12/14/2014Terminated
Z-2160-2013 Class IIJuno DRF System. Mobile X-ray system These are general, multi-function x-ray systems…It has been discovered that the Air Kerma rate information is inconsistent in Continuous Fluoro modes 30x30… Villa Radiology Systems LLC08/02/2013Terminated
Z-2238-2011 Maquet Magnus Carbon-fibre table top; Device Part Number 1180.16xx (x represents a digit…Maquet GmbH's quality monitoring detected that incorrect cover sheets were installed with some Magnus carbon… Maquet Inc.04/15/2011Terminated
Z-0075-2008 Sunisa Flexi-DT Table, Model Numbers: 51335678, 2269647, 2242088-2, 5141609-2, 5115763…Design Problems Including: 1) Hot Brake (Longitudinal Overheating) potential risk of burns 2) Brake Locks… GE Healthcare08/01/2007Terminated