Hamilton Co.

Medical device manufacturer in Reno, NV.

16510(k) clearances
0PMA approvals
9recalls

Device types

510(k) clearances

510(k)DeviceDecision
K961896Microlab 4000, Microlab 4200JQW · Traditional 08/16/1996SE
K943493Discrete Photometric Chemistry AnalyzerJJE · Traditional 01/30/1995SE
K892369Multi-Probe Head PlusJTC · Traditional 06/02/1989SE
K873893LumiconJJQ · Traditional 01/05/1988SE
K871945Microlab atJTC · Traditional 05/29/1987SE
K832205Precision Liquid DispenserJQW · Traditional 08/24/1983SE
K832204Microlab PJQW · Traditional 08/24/1983SE
K832202PB 600 Repeating DispenserJQW · Traditional 08/24/1983SE
K832201Chrom-PrepKZR · Traditional 08/16/1983SE
K832200PRP-1 Reversed Phase Columns for HPLCDPM · Traditional 08/16/1983SE
K832199HC40/HC75 Cation Exchange ResinDNH · Traditional 08/16/1983SE
K832198HC40/HC75 Prepacked ColumsDJY · Traditional 08/12/1983SE
K832197PRP-1 Reversed Phase ResinDMZ · Traditional 08/12/1983SE
K832203Multi-Titer DispenserJTC · Traditional 08/08/1983SE
K822688Digital Diluter/DispensersJQW · Traditional 11/05/1982SE
K801913Microlab M-Microprocessor Diluter/DispJQW · Traditional 09/26/1980SE

Recalls

RecallProductInitiated
Z-1156-2021 Class IIHAMILTON HEATER SHAKER, 115 VAC/ 230 VAC, 750 VA, Power Consumption 41V/ 100W (max.)…There is a risk that the device can start a fire if flammable liquids contact and enter the device. 01/15/2021Open, Classified
Z-0103-2012 Hamilton brand Disposable Syringe Pack for use with Microlab F.A.M.E; Part Number:…Certain lots of syringes have caused an increase in error message "DIS541", which indicates "improper… 09/26/2011Terminated
Z-1999-2009 300 Microliter CO-RE Tips for use with Microlab STAR, manufactured by Hamilton Company…Product Defect-- some tips from the mold cavity 28 are too short and do not always aspirate or dispense… 04/09/2009Terminated
Z-1203-2009 300 microliter CO-RE tips for use with Microlab STAR series instruments, Part Number…Some tips may be occluded and are unable to aspirate or dispense liquid. 12/01/2008Terminated
Z-2233-2008 Hamilton Soft Grip Pipettes, 1 ml adjustable volume, model number 55019-40 Product is…Manufacturing issue with spring may restrict product to drawing less than 1/2 of its stated measured capacity 05/07/2008Terminated
Z-2232-2008 Hamilton Soft Grip Pipettes, 1 ml fixed volume, model number 55019-19 Product is…Manufacturing issue with spring may restrict product to drawing less than 1/2 of its stated measured capacity 05/07/2008Terminated
Z-0718-2008 Hamilton Sample Carriers for the ML STAR line (SMP-CAR-24). Product Code: 866.2500; Part…Incorrectly labeled-- Product has the wrong barcode labeling. The barcode error will not influence the… 06/25/2007Terminated
Z-1169-2007 Microlab F.A.M.E. reagent containers, Part number 148482, box containing 48 containers…Some product containers may be leaking. 03/29/2007Terminated
Z-0723-2007 Hamilton brand Disposable Precision Tips, Part Number 235300 (box containing 504 tips)…Some of the packaged tips have increased force during aspiration, which can lead to pipetting errors such as… 01/30/2007Terminated