Couch, Radiation Therapy, Powered

FDA product code JAI · Class II (moderate risk) · 21 CFR 892.5770 · Radiology

32510(k) clearances
0PMA approvals
17recalls

Manufacturers

510(k) clearances

510(k)DeviceApplicantDecision
K231612Eve Patient Positioner SystemJAI · Traditional Leo Cancer Care05/07/2024SE
K182683Z-Robot Patient Positioning SystemJAI · Traditional Chinan Biomedical Technology, Inc.06/27/2019SE
K170502Patient Positioning SystemJAI · Special Forte Automation Systems, Inc.04/13/2017SE
K160518LEONI ORION SystemJAI · Traditional Leoni Cia Cable System07/14/2016SE
K132084Protura Couch SoftwareJAI · Traditional Med-Tec, Inc. D/B/A Civco Medical Solutions09/26/2013SE
K122413Patient Positioning SystemJAI · Traditional Forte Automation Systems, Inc.09/13/2012SE
K122201Protura Couch SoftwareJAI · Traditional Med-Tec, Inc. D/B/A Civco Medical Solutions08/30/2012SE
K120520Exactrac Robotics Novalis RoboticsJAI · Traditional Brainlab AG06/29/2012SE
K120916Qfix Radiotherapy ChairJAI · Traditional Wfr/Aquaplast Corp.06/20/2012SE
K072898Hexapod Evo RT Couch TopJAI · Special Medical Intelligence Medizintechnik GmbH10/25/2007SE
K071870Hexapod RT Couch TopJAI · Special Medical Intelligence Medizintechnik GmbH07/08/2007SE
K062639Modification to Hexapod RT Couch TopJAI · Special Medical Intelligence Medizintechnik-GmbH-An Elekta09/21/2006SE
K060870AvanzaJAI · Traditional Mds Nordion05/15/2006SE
K060671Kvue Igrt Treatment Table Top, RT-4551KV, Kvue Inserts and Accessories, VariousJAI · Traditional Wfr/Aquaplast Corp.05/04/2006SE
K050422550 TXT Treatment TableJAI · Special Siemens Medical Solutions USA, Inc.03/18/2005SE
K042146Robocouch Patient Support SystemJAI · Traditional Accuray Incorporated09/17/2004SE
K041448Hexapod RT CouchtopJAI · Traditional Medical Intelligence Medizintechnik GmbH06/16/2004SE
K033316Table Tilt DeviceJAI · Traditional Brainlab AG05/14/2004SE
K034054Pro Series Couch Software, Model MT-PRO100JAI · Traditional Med-Tec,Inc.02/20/2004SE
K031866Med-Tec 6 Degree Axis Couch, Model MT-6DACJAI · Traditional Med-Tec,Inc.08/14/2003SE
K013036Nomos Motorized Crane IIJAI · Traditional Nomos Corp.12/07/2001SE
K993522Aktina Medical Physics Corporation Tennis Racquet InsertJAI · Traditional Aktina Medical Physics Corp.01/10/2000SE
K983678Elekta Oncology Systems Precise Treatment TableJAI · Traditional Elekta Instruments, Inc.01/15/1999SE
K982446Dynamic Shielding Radiation TableJAI · Traditional American Biophysics, Inc.09/29/1998SE
K964740The Nomos MinicraneJAI · Traditional Nomos Corp.02/11/1997SE
K941927The Nomos CraneJAI · Traditional Nomos Corp.02/09/1995SE
K910648Therapy Chair SystemJAI · Traditional Radiation Technology, Inc.07/22/1991SE
K910002Genesys and the RoiJAI · Traditional The Complete Systems Corp. Genesys07/22/1991SE
K910971Z XT Radiation Therapy Treatment TableJAI · Traditional Siemens Medical Laboratories, Inc.05/03/1991SE
K855063Universal Patient Chair Uni 2000XJAI · Traditional Siemens Medical Solutions USA, Inc.01/30/1986SE
K834201TCT-1 Treatment CouchJAI · Traditional Therados, Inc.03/05/1984SE
K837152Therac 25 Linear AcceleratorJAI · Traditional Atomic Energy of Canada03/22/1983SE

Recalls

RecallProductFirmInitiated
Z-0399-2024 Class IIORION System with software OSS v6.0 and OSS v7.0- An electro-mechanical robotic arm for…Users of the patient positioning system ORION System can be faced with a sudden short-term acceleration or… Leoni Cia Cable Systems10/06/2023Open, Classified
Z-0398-2024 Class IIORION System with software OSS v6.0 and OSS v7.0- An electro-mechanical robotic arm for…Users of the patient positioning system ORION System can be faced with a sudden short-term acceleration or… Leoni Cia Cable Systems10/06/2023Open, Classified
Z-2535-2018 Class IIHexaPOD evo RT Couch Top (also known as HexaPOD evo Module), a component of the HexaPOD…Upon completion of a 6D workflow, the HexaPOD evo Module may be in a tilted state if it is moved to the… Elekta, Inc.05/16/2018Terminated
Z-0671-2018 Class IIProtura Software which utilizes Elekta's iCOM interface: MT6XSM1.4.0, MT6XSM1.4.0-1…When an error message remains displayed and is not cleared in the Protura software with the Elekta pedestal… Med Tec Inc11/08/2017Terminated
Z-2537-2018 Class IIPatient Positioning System with KRC2 controller using software versions 2.3.1 2.3.10…Communications between the Patient Positioning System and the accuracy filter can periodically fail with no… Forte Automation Systems Inc09/05/2017Terminated
Z-1992-2016 Class IIProtura Robotic Couch System Software, versions 1.6.1 (Part Number MT6XSM1.6.1), 1.7.0…When using the recalled product in split shift mode, the non-sub-millimeter positioning has been found to be… Med Tec Inc03/31/2016Terminated
Z-1238-2015 Class IIElekta Precise Treatment TableIt is possible to position the Treatment Table with errors greater than 5mm and no inhibits are displayed… Elekta, Inc.01/29/2015Terminated
Z-1514-2014 Class IIHexaPOD evo RT Couchtop. To support and aid in positioning a patient during radiation…If screws are not properly tightened with a torque wrench they may become loose over time. Elekta, Inc.04/17/2014Terminated
Z-0787-2014 Class IIPRIMUS, ONCOR, ARTISTE Linac systems with component 550 TxT Treatment Table. TT-A, TT-D…Update to correct the possibility for patients or operators to have their fingers trapped or pinched between… Siemens Medical Solutions USA, Inc12/05/2013Terminated
Z-1155-2013 Class IIRoboCouch Patient Positioning System Product Usage: is intended for use in the support…A5 gearboxes responsible for pitch (head up and head down) and roll (patient left and right) motions of the… Accuray Incorporated03/27/2013Terminated
Z-1072-2013 Class IIPrecise Treatment Table. To be used as part of radiation therapy treatment process.The Column rotation can accidentally be moved to a different position which in the locked position. Elekta, Inc.03/14/2013Terminated
Z-2023-2011 Siemens brand 550 TxT Patient Treatment Table, part number 7346534; Product is…Potential for causing overheating of the power supply during treatment, and potential for unexpected table… Siemens Medical Solutions USA, Inc03/31/2010Terminated
Z-0166-2011 Siemens brand 550 TxT Patient Table, Part No. 7346534, Distributed by and/or…An increase in voltage may cause a short circuit of a power transistor that may cause a smoldering and… Siemens Medical Solutions USA, Inc03/31/2010Terminated
Z-0853-2011 RoboCouch Patient Support System, model number 025007, a subsystem of the Cyberknife…Mechanical Failure-- Patient Support System's table top may unexpectedly descend several inches. Accuray Inc07/21/2009Terminated
Z-0856-2009 RoboCouch Patient Support System, a component of the CyberKnife Robotic Radiosurgery…Product may not be tensioned properly, potentially causing unexpected rotation or descent. Accuray Inc10/30/2008Terminated
Z-1030-2011 Precise Treatment Table The Precise Treatment Table is intended as a universal patient…Possible error in the table longitudinal position. Elekta, Inc.03/10/2008Terminated
Z-1432-2010 Precise Treatment Table Intended as a universal patient treatment support and…In some instances, the bolts which are supplied with the table have sheared off, resulting in inability to… Elekta, Inc.01/11/2007Terminated